Revision Notes MCQ Bank SAQ Bank Study Cards Courses Teachers Blog

Time of Flight

A concise AQA revision guide to the time of flight (TOF) mass spectrometer: how ions are made by electrospray or electron impact, accelerated to the same kinetic energy, drift along the flight tube and are detected, and how flight time gives m/z.

Paper 1
AQA
3.1.1 Atomic Structure
7405/1
AQA specification5 spec points in this lesson
  • 3.1.1.2iv-a
  • 3.1.1.2iv-b
  • 3.1.1.2iv-c
  • 3.1.1.2iv-d
  • 3.1.1.2iv-e
What these spec points say
  • 3.1.1.2iv-a understand ionisation in a simple time of flight (TOF) mass spectrometer
  • 3.1.1.2iv-b understand acceleration in a simple time of flight (TOF) mass spectrometer, including giving all ions constant kinetic energy
  • 3.1.1.2iv-c understand ion drift in a simple time of flight (TOF) mass spectrometer
  • 3.1.1.2iv-d understand ion detection in a simple time of flight (TOF) mass spectrometer
  • 3.1.1.2iv-e understand data analysis in a simple time of flight (TOF) mass spectrometer

Time of Flight: The Ion Race

Choose a step to watch ions being made, accelerated to the same kinetic energy, raced along the flight tube and detected.

Drag to rotate
Step
View

Sample molecule X H⁺ (proton) Electron ¹²C⁺ ion (light) Copper ion (heavy)

© Dr. Mohammed Al-Fatah – onlinelearningsystem.net

1

Before You Start

This page builds on GCSE ideas about ions, charge and moving particles.

  • An atom that loses an electron becomes a positive ion.
  • Opposite charges attract, so a positive ion moves towards a negative plate.
  • Kinetic energy = ½ × mass × speed², so at the same kinetic energy a heavier particle moves more slowly.
  • Speed = (distance) / (time), so a slower particle takes longer to cover the same distance.
Before you start

GCSE Recap: Isotopes, Ions and Moving Particles

Five quick GCSE questions on the ideas this instrument is built on.

2

Why AQA Uses the Time of Flight Instrument

The Mass Spectrometer page describes an instrument that bends ions in a magnetic field.

AQA examines a different design, the time of flight (TOF) mass spectrometer, which has no magnet at all.

Ions are given the same kinetic energy and then race along an empty tube: lighter ions move faster and reach the detector first, so the flight time reveals the mass-to-charge ratio.

Whatever the design, the spectrometer produces the same output: a plot of relative abundance against m/z. Everything on the RAM Calculations and Predicting Diatomic Mass Spectra pages still applies.

The four stages of a TOF mass spectrometer. The whole instrument is kept under vacuum so that ions do not collide with air molecules.

Key idea: TOF separates ions by how long they take to cover a fixed distance. Same kinetic energy, different mass, therefore different speed and different flight time.

3

Stage 1: Ionisation

Ions are needed because only charged particles can be accelerated by an electric field and counted by the detector. AQA names two methods.

MethodHow it worksIon formedUsed for
Electrospray ionisationThe sample is dissolved in a volatile, polar solvent and pushed through a fine hypodermic needle held at a high positive voltage. The tiny droplets lose solvent and each molecule picks up a proton from the solvent.XH+, so the ion has a mass one unit greater than the molecule: X + H+ → XH+Large, fragile molecules such as proteins that would break up under electron impact
Electron impactThe sample is vaporised and bombarded with high-energy electrons from an electron gun. Each impact knocks one electron out of the molecule or atom.X+, a molecular ion or atomic ion with the same mass as the original particle: X → X+ + e−Elements and small, robust molecules

The distinction matters in calculations.

An electrospray peak at m/z 181 for a singly charged ion means the molecule itself has a relative molecular mass of 180, because one proton (mass 1) was added.

An electron-impact peak at m/z 180 means the molecular mass is 180.

Exam sentence: Electrospray: the sample gains a proton to form XH⁺. Electron impact: a high-energy electron knocks an electron out of the sample to form X⁺. Write the equation and state which ion forms.

Electrospray adds a proton to give XH⁺ at Mᵣ + 1; electron impact removes an electron to give X⁺ at Mᵣ.

Check your understanding

Quick Check: Two Ionisation Methods

Decide what each method does to the mass of the particle before it is detected.

4

Stage 2: Acceleration to the Same Kinetic Energy

The positive ions are attracted towards a negatively charged plate. Every ion with the same charge passes through the same potential difference, so each gains the same kinetic energy, whatever its mass.

Kinetic energy is linked to mass and speed by

KE = ½ m v²   so   v = √(2KE / m)

Because KE is the same for every ion, a heavier ion must move more slowly than a lighter one. Doubling the mass reduces the speed by a factor of √2, not by half.

Key idea: Same kinetic energy is the whole point. If ions had the same speed instead, mass could not be measured from flight time at all.

Check your understanding

Quick Check: Same Energy, Different Speed

Five rapid questions on what the acceleration stage fixes and what it leaves to the mass.

5

Stage 3: Ion Drift Along the Flight Tube

After the acceleration region there is no further field. The ions drift at constant speed along an evacuated tube of fixed length d, so their flight time is

t = (d) / (v)   and, substituting for v,   t = d √((m) / (2KE))

Flight time is proportional to the square root of the mass. Ions of higher mass arrive later. Because the tube is a vacuum, no collisions slow the ions or knock them off course.

IonMass of one ion / kgSpeed for KE = 1.20 × 10−13 JFlight time for d = 1.00 m
12C+1.99 × 10−263.47 × 106 m s−12.88 × 10−7 s
63Cu+1.05 × 10−251.51 × 106 m s−16.60 × 10−7 s
208Pb+3.45 × 10−258.34 × 105 m s−11.20 × 10−6 s

The mass of one ion in kilograms is the relative mass divided by the Avogadro constant and converted from grams: m = (M) / (1000) / L. For 63Cu that is (0.063) / (6.022 × 1023) = 1.05 × 10−25 kg.

Every 1+ ion gets the same kinetic energy, so heavier ions move more slowly and take longer to cross the flight tube.

Check your understanding

Quick Check: Scaling Flight Times

Work each one out on paper, then flip the card to see the full working.

Check your understanding

Quick Check: Explain the Two Boron Peaks

Write a short explanation, then compare it with the mark points and the model answer.

6

Stage 4: Detection and Data Analysis

The ions strike a negatively charged detector plate. Each positive ion gains an electron from the plate, and that flow of electrons is a tiny electric current.

The size of the current is proportional to the number of ions arriving, so it measures abundance; the time of arrival gives m/z.

A computer converts the arrival times into m/z values using the flight-time equation and plots relative abundance against m/z: the mass spectrum. For an element the spectrum shows one peak per isotope; for a compound it shows the molecular ion and any fragments.

Exam sentence: Ions are detected when they gain an electron at the detector plate, producing a current whose size depends on the number of ions. The flight time gives m/z and the current gives abundance.

7

Worked Calculation: Flight Time of an Ion

Question. A 35Cl+ ion is accelerated to a kinetic energy of 1.35 × 10−13 J and drifts along a 0.850 m flight tube. Calculate its flight time. (L = 6.022 × 1023 mol−1)

  1. Mass of one ion: m = (0.035) / (6.022 × 1023) = 5.81 × 10−26 kg
  2. Speed: v = √((2 × 1.35 × 10−13) / (5.81 × 10−26)) = √(4.65 × 1012) = 2.16 × 106 m s−1
  3. Flight time: t = (0.850) / (2.16) × 106 = 3.94 × 10−7 s

Working backwards. An unknown ion in the same instrument takes 4.21 × 10−7 s. Its speed is v = (0.850) / (4.21) × 10−7 = 2.02 × 106 m s−1.

Its mass is m = (2KE) / (v²) = (2 × 1.35 × 10−13) / ((2.02 × 106)²) = 6.62 × 10−26 kg.

The molar mass is M = m × L × 1000 = 39.9 g mol−1, so the ion is 40Ar+.

Key idea: Keep everything in SI units: kilograms, metres, joules, seconds. Convert the relative mass to the mass of one ion in kilograms before you touch the equation.

Check your understanding

Quick Check: Identify the Ion

Run the worked example backwards to find the relative mass of an unknown ion.

Check your understanding

Quick Check: Pick the Accurate Statement

In each round, choose the one statement that is accurate, drawing on the whole instrument.

8

Common Exam Points

  • Saying ions are separated by a magnetic field. There is no magnet in a TOF instrument: separation happens by flight time in a field-free tube.
  • Giving the ions the same speed. They have the same kinetic energy; speed depends on mass.
  • Forgetting the extra proton in electrospray. The peak appears at M + 1, so subtract 1 to find the relative molecular mass.
  • Using the relative mass in grams. Divide by the Avogadro constant and convert to kilograms first.
  • Describing detection as “the ion hits the plate”. The mark is for the ion gaining an electron and the resulting current.

Exam sentence: In a time of flight mass spectrometer ions with the same kinetic energy but different masses travel at different speeds, so they reach the detector at different times; the flight time is used to find m/z.

FAQs

These questions cover the points students most often get wrong on time of flight.

When is electrospray used instead of electron impact?

Electrospray is used for large, fragile molecules such as proteins, which would break up under electron impact. Electron impact suits elements and small, robust molecules.

Why do all the ions have the same kinetic energy?

Every 1+ ion is accelerated through the same potential difference, so each gains the same kinetic energy whatever its mass. That is why speed, and so flight time, depends on mass.

Why is flight time proportional to the square root of the mass?

From KE = ½mv², v = √(2KE / m). Since t = (d) / (v), t = d√((m) / (2KE)). Doubling the mass multiplies the flight time by √2, not by 2.

How are the ions detected?

Each positive ion gains an electron at the detector plate. The flow of electrons is a current proportional to the number of ions arriving, and the arrival time gives m/z.

Why does electrospray give a peak at M+1?

Each molecule gains a proton, H+, to form XH+. The ion is one mass unit heavier than the molecule, so subtract 1 from the m/z to find the relative molecular mass.

Dr. Mohammed Al-Fatah

Written by: Dr. Mohammed Al-Fatah

Chemistry specialist revision notes for A Level Chemistry.

View LinkedIn Profile

Copyright notice: This OLS revision content, including the explanations, layout, diagrams, tables and embedded learning structure, is authored for Online Learning System by Dr. Mohammed Al-Fatah. It may not be copied, reproduced, redistributed or adapted without written permission.