Revision Notes MCQ Bank SAQ Bank Study Cards Courses Teachers Blog

Gas Chromatography and Retention Times

A concise revision guide to gas chromatography: how the column separates a mixture, retention times, and why chromatography is joined to mass spectrometry.

Paper 2 AQA
3.3.16 Chromatography
7405/2
AQA specification3 spec points in this lesson
  • 3.3.16ii-c
  • 3.3.16v-a
  • 3.3.16vi
What these spec points say
  • 3.3.16ii-c know the principles of gas chromatography (GC)
  • 3.3.16v-a compare retention times with standards to identify different substances
  • 3.3.16vi know the use of mass spectrometry to analyse the components separated by GC
2

How Gas chromatography Works

Gas chromatography (GC) separates mixtures of volatile substances. The mixture is carried as a vapour through a long column.

PartDescription
Mobile phasean inert (unreactive) carrier gas, such as nitrogen or helium
Stationary phasea solid, or a solid coated with a high-boiling liquid, packed in the column
Columna long, thin, coiled tube inside an oven
Ovenkeeps the column at a controlled high temperature
Detectorresponds as each component leaves the column

What happens to the sample

  1. A small sample is injected and vaporised at the hot injection port.
  2. The carrier gas sweeps the vapour into the column under pressure.
  3. Each component keeps dissolving in the liquid stationary phase and returning to the gas.
  4. A component that is more soluble in the stationary phase spends less time moving, so it travels more slowly.
  5. The components reach the detector one after another, and each gives a peak on the chromatogram.

A gas chromatograph: inert carrier gas, injection port, long coiled column in an oven with a high-boiling liquid on a solid support, detector and recorder.

Key idea: In gas chromatography the mobile phase is an inert gas and the separation depends on how long each component spends dissolved in, or held by, the stationary phase.

3

Retention Time

Definition: Retention time: the time from the injection of the sample to the detection of a component, that is, the time the component takes to pass through the column.

What affects retention time

  • Volatility: a component with a lower boiling point spends more time in the gas, so it has a shorter retention time.
  • Attraction to the stationary phase: a component that is more soluble in it, or more strongly held by it, has a longer retention time.
  • Conditions: column temperature, carrier gas flow rate, column length and the stationary phase used.

Identifying components

Under fixed conditions each substance has its own retention time. Run pure known substances (standards) under the same conditions and compare.

StandardRetention time / min
Ethanol1.8
Propan-1-ol3.2
Butan-1-ol5.5
Pentan-1-ol8.1

A mixture gives three peaks, at 1.8, 3.2 and 5.5 min. It contains ethanol, propan-1-ol and butan-1-ol. There is no peak at 8.1 min, so it contains no pentan-1-ol.

A gas chromatogram with peaks at 1.8, 3.2 and 5.5 min, identified by comparing with the retention times of standards run under the same conditions.

  • The number of peaks shows the number of components detected.
  • In this series the retention time rises with chain length, as the alcohols become less volatile.
Check your understanding

Check: The Instrument and Retention Times

Describe the phases in gas chromatography and use retention times to identify the components of a mixture, with data not used on this page.

Check your understanding

Quick Check: Which Alkane Comes Out First?

Use volatility to predict the order in which four new compounds reach the detector.

4

GC-MS: Gas Chromatography With Mass Spectrometry

Retention times alone have limits.

  • Similar compounds can have very similar retention times.
  • A retention time identifies a substance only if a standard is available to compare with.
  • A new or unexpected compound cannot be identified this way.

Separate, then identify

In GC-MS the gas chromatograph is connected to a mass spectrometer. Mass spectrometry is used to analyse the components separated by GC.

  1. The GC column separates the components of the mixture.
  2. Each component passes, in turn, straight into the mass spectrometer.
  3. A mass spectrum is recorded for each one.
  4. Each spectrum is compared with a database of known spectra to identify the compound.

GC-MS: the chromatograph separates the mixture, the mass spectrometer records a spectrum for each component, and a database match identifies it.

Uses

UseExample
Forensicsidentifying substances in samples from a crime scene or a fire
Drug testing in sportdetecting banned substances in blood or urine
Environmental analysismeasuring pollutants and pesticides in water, air and food
Airport securitydetecting traces of explosives

Key idea: Chromatography separates; mass spectrometry identifies. Together they can identify every component of a complex mixture, even in tiny amounts.

Check your understanding

Quick Check: Why Add a Mass Spectrometer?

Pick the one accurate statement in each set, using new analytical problems.

5

Common Exam Points

Say

  • “Retention time is the time from injection to detection of the component.”
  • “The mobile phase is an inert carrier gas such as nitrogen or helium.”
  • “The component is identified by comparing its retention time with that of a known substance under the same conditions.”

Do not say

  • “The first peak is the largest molecule” (the first peak is the component least retained by the stationary phase).
  • “The carrier gas reacts with the sample” (it is inert).
  • “The retention time proves the identity” (it must be compared with a standard).

Watch for

  • Naming both phases correctly: gas mobile phase, liquid or solid stationary phase.
  • GC-MS questions: say that GC separates and the mass spectrum identifies by comparison with a database.
  • Stating that conditions must be kept the same when retention times are compared.
Check your understanding

Check: Chromatography With Mass Spectrometry

Interpret chromatograms and explain how chromatography joined to mass spectrometry identifies the components of a mixture, in contexts not used on this page.

FAQs

Use these quick answers to check gas chromatography and retention times.

What are the two phases in gas chromatography?

The mobile phase is an inert carrier gas such as nitrogen or helium. The stationary phase is a high-boiling liquid coated on a solid support inside a long coiled column, which is kept in an oven.

What is retention time?

It is the time from injection of the sample to the detection of a component at the end of the column. Components more soluble in the liquid stationary phase are held back for longer and so have longer retention times.

How is a component identified by gas chromatography?

Compare its retention time with that of a known standard run under exactly the same conditions: same column, temperature and carrier gas flow rate. Different compounds can have similar retention times, so a match is not absolute proof.

Why is the column kept in an oven?

The sample must stay vaporised so that the carrier gas can sweep it through the column. The oven also keeps the temperature constant, because retention times change with temperature and comparison with standards would otherwise be unreliable.

Why is gas chromatography joined to mass spectrometry?

Chromatography separates the mixture, and each component then passes into a mass spectrometer. Its mass spectrum is compared with a database to identify it with certainty. The method is used in forensics, environmental analysis, airport security and drug testing in sport.

Dr. Mohammed Al-Fatah

Written by:
Dr. Mohammed Al-Fatah

Chemistry specialist revision notes for A Level Chemistry.

View LinkedIn Profile

Copyright notice: This OLS revision content, including the explanations, layout, diagrams, tables and embedded learning structure, is authored for Online Learning System by Dr. Mohammed Al-Fatah. It may not be copied, reproduced, redistributed or adapted without written permission.