Revision Notes MCQ Bank SAQ Bank Study Cards Courses Teachers Blog

Gas Chromatography and Retention Times

A concise revision guide to gas chromatography: how the column separates a mixture, retention times, peak areas and the proportions of the components, and interpreting a gas–liquid chromatogram.

A Level
Topic 37: Analytical techniques
9701 Paper 4
Cambridge International specification5 spec points in this lesson
  • 37.2.1(a)
  • 37.2.1(b)
  • 37.2.1(c)
  • 37.2.2
  • 37.2.3
What these spec points say
  • 37.2.1(a) describe and understand the term stationary phase in gas/liquid chromatography; a high boiling point non-polar liquid (on a solid support)
  • 37.2.1(b) describe and understand the term mobile phase in gas/liquid chromatography; an unreactive gas
  • 37.2.1(c) describe and understand the term retention time
  • 37.2.2 interpret gas/liquid chromatograms in terms of the percentage composition of a mixture
  • 37.2.3 explain retention times in terms of interaction with the stationary phase
1

Before You Start

This page uses the ideas of a mobile phase and a stationary phase from Chromatography and Rf Values. Here the mobile phase is a gas.

2

How Gas–liquid chromatography Works

Gas–liquid chromatography (GC) separates mixtures of volatile substances. The mixture is carried as a vapour through a long column.

PartDescription
Mobile phasean inert (unreactive) carrier gas, such as nitrogen or helium
Stationary phasea high boiling point, non-polar liquid on a solid support
Columna long, thin, coiled tube inside an oven
Ovenkeeps the column at a controlled high temperature
Detectorresponds as each component leaves the column

What happens to the sample

  1. A small sample is injected and vaporised at the hot injection port.
  2. The carrier gas sweeps the vapour into the column under pressure.
  3. Each component keeps dissolving in the liquid stationary phase and returning to the gas.
  4. A component that is more soluble in the stationary phase spends less time moving, so it travels more slowly.
  5. The components reach the detector one after another, and each gives a peak on the chromatogram.

A gas chromatograph: inert carrier gas, injection port, long coiled column in an oven with a high-boiling liquid on a solid support, detector and recorder.

Key idea: In gas chromatography the mobile phase is an inert gas and the separation depends on how long each component spends dissolved in, or held by, the stationary phase.

3

Retention Time

Definition: Retention time: the time from the injection of the sample to the detection of a component, that is, the time the component takes to pass through the column.

What affects retention time

  • Volatility: a component with a lower boiling point spends more time in the gas, so it has a shorter retention time.
  • Attraction to the stationary phase: a component that is more soluble in it, or more strongly held by it, has a longer retention time.
  • Conditions: column temperature, carrier gas flow rate, column length and the stationary phase used.

Identifying components

Under fixed conditions each substance has its own retention time. Run pure known substances (standards) under the same conditions and compare.

StandardRetention time / min
Ethanol1.8
Propan-1-ol3.2
Butan-1-ol5.5
Pentan-1-ol8.1

A mixture gives three peaks, at 1.8, 3.2 and 5.5 min. It contains ethanol, propan-1-ol and butan-1-ol. There is no peak at 8.1 min, so it contains no pentan-1-ol.

A gas chromatogram with peaks at 1.8, 3.2 and 5.5 min, identified by comparing with the retention times of standards run under the same conditions.

  • The number of peaks shows the number of components detected.
  • In this series the retention time rises with chain length, as the alcohols become less volatile.
Check your understanding

Check: The Instrument and Retention Times

Describe the phases in gas chromatography and use retention times to identify the components of a mixture, with data not used on this page.

Check your understanding

Quick Check: Which Alkane Comes Out First?

Use volatility to predict the order in which four new compounds reach the detector.

4

Peak Areas and Amounts

The area under each peak is proportional to the amount of that component in the mixture. Comparing areas gives the proportions of the components.

percentage of a component = (area of its peak) / (total area of all peaks) × 100

Worked example

A chromatogram has three triangular peaks, X, Y and Z. Their bases are 0.4, 0.5 and 0.6 min wide and their heights are 60, 120 and 60 units. Find the percentage composition.

Step 1.
Area = ½ × base × height
X: ½ × 0.4 × 60 = 12.0
Y: ½ × 0.5 × 120 = 30.0
Z: ½ × 0.6 × 60 = 18.0

Step 2. Total area = 12.0 + 30.0 + 18.0 = 60.0.

Answer.
X = (12.0) / (60.0) × 100 = 20.0%
Y = (30.0) / (60.0) × 100 = 50.0%
Z = (18.0) / (60.0) × 100 = 30.0%

Peak areas from ½ × base × height: 12.0, 30.0 and 18.0 units, total 60.0, giving 20.0%, 50.0% and 30.0% of the mixture.

  • Use the area, not the height: peak Z is as tall as peak X but wider, so it represents more substance.
  • The method assumes the detector responds equally to each component.

Exam focus: Retention time identifies a component. Peak area shows how much of it is present.

Check your understanding

Quick Check: Work Out the Composition

Work each step on paper, then flip the card to check your working.

5

Limits of Retention Times

  • Retention times are only comparable under identical conditions.
  • Similar compounds can have very similar retention times, so their peaks may overlap.
  • An unknown compound may have no standard to compare with.

For these reasons a gas chromatograph is often connected to a mass spectrometer, which gives a spectrum for each separated component.

Remember: A retention time suggests an identity only by comparison with a known substance run under the same conditions.

Check your understanding

Quick Check: Why Add a Mass Spectrometer?

Pick the one accurate statement in each set, using new analytical problems.

6

Common Exam Points

Say

  • “Retention time is the time from injection to detection of the component.”
  • “The mobile phase is an inert carrier gas such as nitrogen or helium.”
  • “The component is identified by comparing its retention time with that of a known substance under the same conditions.”
  • “The area under each peak is proportional to the amount of that component.”

Do not say

  • “The first peak is the largest molecule” (the first peak is the component least retained by the stationary phase).
  • “The carrier gas reacts with the sample” (it is inert).
  • “The tallest peak is the most abundant component” (compare areas, not heights).

Watch for

  • Naming both phases correctly: gas mobile phase, liquid or solid stationary phase.
  • Percentage composition: add all the peak areas first, then divide.
  • Stating that conditions must be kept the same when retention times are compared.
Check your understanding

Check: Interpreting Chromatograms

Interpret gas chromatograms: identify components from retention times and find the percentage composition from peak areas, with data not used on this page.

FAQs

Use these quick answers to check gas chromatography and retention times.

What are the two phases in gas chromatography?

The mobile phase is an inert carrier gas such as nitrogen or helium. The stationary phase is a high-boiling liquid coated on a solid support inside a long coiled column, which is kept in an oven.

What is retention time?

It is the time from injection of the sample to the detection of a component at the end of the column. Components more soluble in the liquid stationary phase are held back for longer and so have longer retention times.

How is a component identified by gas chromatography?

Compare its retention time with that of a known standard run under exactly the same conditions: same column, temperature and carrier gas flow rate. Different compounds can have similar retention times, so a match is not absolute proof.

What does the area under a peak show?

The area is proportional to the amount of that component in the sample. Percentage composition = (area of one peak) / (total area of all peaks) × 100. Compare areas, not heights, because peaks can be broad or narrow.

Which substances are suitable for gas chromatography?

The sample is injected, vaporised and carried through the column as a gas, so the components must be volatile and must not decompose at the temperature of the oven.

Dr. Mohammed Al-Fatah

Written by:
Dr. Mohammed Al-Fatah

Chemistry specialist revision notes for A Level Chemistry.

View LinkedIn Profile

Copyright notice: This OLS revision content, including the explanations, layout, diagrams, tables and embedded learning structure, is authored for Online Learning System by Dr. Mohammed Al-Fatah. It may not be copied, reproduced, redistributed or adapted without written permission.